FM54™ Air Purifying Respirator

$878.40 USD $878.40 USD

The Avon Protection fire hardened FM54 Air Purifying Respirator provides Specialist Operators maximum protection and total flexibility. The FM54 provides protection to the face, eyes and respiratory tract from Chemical, Biological, Radiological and Nuclear (CBRN) threats, Riot Agents, Toxic Industrial Chemicals (TICs) and Toxic Industrial Materials (TIMs) while maintaining extreme user flexibility as mission profiles change. 

The U.S. Government has certain controls over the FM54™ Air Purifying Respirator and prohibits the exporting, selling, transferring, transporting, or shipping of the product outside the U.S. This restriction applies whether the product is in its original form or has been incorporated into other items without first obtaining approval from the U.S. government, or as authorized by U.S. law and regulations. This product is subject to Export Administration Regulations (EAR) with a classification of 1A004.



Size: small
Performance
Technical Data
CBRN Agent Resistance Requirement FM54 Performance
Mustard Vapor (HD) 36 hours > 36 hours
Mustard Liquid (HD) 36 hours > 36 hours
Sarin (GB) 36 hours > 36 hours
Laboratory protection factor performance (sodium chloride) 2,000 > 10,000
Breathing Performance
Re-breathed CO2 < 1%
Inhalation Resistance 30 L/Min < 5 mm WG
95 L/Min < 12 mm WG
160 L/Min < 23 mm WG
Exhalation Resistance negative pressure mode 85 L/Min < 8 mm WG
160 L/Min < 12 mm WG
Weight
FM54 mask (excluding filter < 0.65 kg (1.43 lbs)
Field of View
Visual Field Score (NIOSH CBRN Standard) 96
Materials Used
FM54 Mask Chlotobutyl / Silicone rubber & Polyurethane
Hydration
Drinking flow rate 230 mL/min
Sizing
*ALL SALES ARE FINAL. OPEN BOX RETURNS WILL NOT BE ACCEPTED.

Please select the correct size according to the sizing chart guide.

NOTE: For proper mask fit, faces must be clean shaven. Facial hair, sideburns, bangs and headwear may prevent a protective facepiece from forming and/or maintaining a tight-fitting seal on someone’s face. It is recommended the user be clean shaven and/or hair pulled back for sizing and using the respirator to ensure an appropriate seal.

To ensure you have selected the correct size you should perform a negative pressure test. The negative pressure test can be performed by putting the mask on your face, breathe out, then block the inhalation valve and take a deep breath. For the FM50 you will need to block both inhalation valves before taking a breath. The mask should collapse to the face. If you experience a tight seal to your face then the mask has the right fit.

If you are still unsure of your size or are certain you are going to be in a hazardous environment and need to ensure the most accurate sizing you may purchase a Sizing Tool.

*Except in the rare case of defective product. Please contact customer service for further instruction in this instance.

Warnings and Limitations of Use
  • Always perform a satisfactory negative pressure leak test before using this respirator.
  • Do not use in confined spaces such as stills, tanks or sewers. This device does not provide supplied breathable air.
  • It is unlikely that the requirements for inward leakage of the system will be met if facial hair, or spectacle side arms pass under the face seal of the full face mask.
  • Do not use this equipment in Oxygen deficient atmospheres (<19.5% Oxygen) or for airborne contaminants or pollutants for which the approved filter canister(s) will not provide adequate protection.
  • Do not use this equipment in Oxygen enriched atmospheres (> 22.5% Oxygen).
  • System set-up, pre-check, donning, doffing, cleaning and maintenance must be performed in an area known to be free of contaminants.
  • Do not use if any system component demonstrates signs of wear or damage.
  • Do not use in areas where the head harness may be exposed directly to flame.

Potential misuse of the equipment may result in serious, irreversible respiratory harm or death. These actions include:

  • Firefighting.
  • Modifying, removing or re-configuring any of the system components other than as recommended by the manufacturer.
  • Adapting the system to accommodate attachments or apparatus not approved for use by the manufacturer.
  • Re-using the equipment without appropriate decontamination or following impact or tear damage without inspection and testing, even though contamination or damage may not be apparent.
  • Use with unapproved filter canisters.
Resources

FM54™ Brochure

Frequently Asked Questions