Skip to content
Sold Out

PC50™ Response Kit

$549.00 USD $549.00 USD

The Avon Protection PC50™ protective mask is based on the widely deployed 50 Series masks, and is designed to provide protection in dangerous and contaminated environments that demand a robust, field-proven competitively-priced military pedigree product that meets their operational needs.

This gas mask kit includes:

  • PC50™ Air Purifying Respirator
  • A CTCF50 Riot Agent filter
  • A sunlight outsert
  • A clear outsert

The PC50 is available in three sizes, with either left or right hand 40mm canister mounts that accept traditional or conformal filters. The standard communication port allows the ability to integrate with existing radios. The PC50 may be fitted with a vision correction system and a variety of outserts for specific operational situations. 

The U.S. Government has certain controls over the PC50™ Air Purifying Respirator and prohibits the exporting, selling, transferring, transporting, or shipping of the product outside the U.S. without first obtaining approval from the U.S. government, or as authorized by U.S. law and regulations. This restriction applies whether the product is in its original form or has been incorporated into other items. This product is subject to Export Administration Regulations (EAR) with a classification of 1A004.

Product shipped in fulfillment of e-commerce orders may be more than one year old.

PLEASE NOTE ALL SALES ARE FINAL. OPEN BOX RETURNS WILL NOT BE ACCEPTED. 
In the rare case of a defective product, please refer to our returns policy and contact customer service for further instructions.

Please note, this item will ship within 10 days.

Size: small
Performance

The Avon Protection PC50™ protective mask is based on the widely deployed 50 Series masks, and is designed to provide protection in dangerous and contaminated environments that demand a robust, field-proven competitively-priced military pedigree product that meets their operational needs.

This gas mask kit includes:

  • PC50™ Air Purifying Respirator
  • A CTCF50 Riot Agent filter
  • A sunlight outsert
  • A clear outsert

The PC50 is available in three sizes, with either left or right hand 40mm canister mounts that accept traditional or conformal filters. The standard communication port allows the ability to integrate with existing radios. The PC50 may be fitted with a vision correction system and a variety of outserts for specific operational situations. 

The U.S. Government has certain controls over the PC50™ Air Purifying Respirator and prohibits the exporting, selling, transferring, transporting, or shipping of the product outside the U.S. without first obtaining approval from the U.S. government, or as authorized by U.S. law and regulations. This restriction applies whether the product is in its original form or has been incorporated into other items. This product is subject to Export Administration Regulations (EAR) with a classification of 1A004.

Product shipped in fulfillment of e-commerce orders may be more than one year old.

PLEASE NOTE ALL SALES ARE FINAL. OPEN BOX RETURNS WILL NOT BE ACCEPTED. 
In the rare case of a defective product, please refer to our returns policy and contact customer service for further instructions.

Please note, this item will ship within 10 days.

The PC50 is approved for use with the CTCF50 Canister providing protection against CS/CN agents in both vapor and aerosol form and particulate matter. The PC50 is also approved for use with the CFP100 Canister providing protection against particulates only. And NIOSH approved (TC-14G-0316) (TC-84A-9233).

Breathing Performance PC50 Performance
Inhalation resistance without filter:
30 l/min 0.5 mbar
90 l/min 1.5mbar
160 l/min 3.5 mbar
Exhalation resistance 85l/min (with CTCF50 filter) 1.9 mbar
Mask weight (excluding filter) 550 grams
Visual Field Score (VFS) >90
Sizing

Please select the correct size according to the sizing chart found in the photo gallery for this product.

  • Clean-shaven faces are required for the Avon FM50™ to fit properly. The gas mask and filter should form a tight seal on the face to ensure protection.
  • Facial hair, sideburns, bangs and headwear may prevent a protective facepiece from forming and/or maintaining a tight-fitting seal on someone’s face. It is recommended the user be clean shaven and/or hair pulled back for sizing and using the respirator to ensure an appropriate seal.
  • Use the negative pressure test to confirm the right fit for your gas mask kit.
Here's how:
  • Put the mask on your face and breathe out.
  • Block the inhalation valve and take a deep breath.
  • Specifically for the Avon FM50™, you will need to block both inhalation valves before taking a breath.
  • The mask should then collapse to the face.
  • If you experience a tight seal to your face, then the mask has the right fit.

If you are still unsure of your size and need to ensure the most accurate sizing, purchase our Sizing Tool for the perfect fit.

Warnings and Limitations of Use
  • Always perform a negative pressure leak test before using this respirator mask with filters.
  • This gas mask with filters is not suitable for use in confined spaces such as stills, tanks or sewers. This device does not provide supplied breathable air.
  • If you have facial hair or wear glasses, the mask may not seal properly, reducing its protection.
  • Do not use this respirator mask in environments with low oxygen (less than 19.5%) or in areas with airborne contaminants/pollutants the filter can't protect against.
  • Do not use this gas mask and filter in oxygen-enriched atmospheres (> 22.5% Oxygen).
  • Set up, check, donning, doffing, clean, and maintain the gas mask kit in a clean area free of contaminants.
  • Do not use if any system component demonstrates signs of wear or damage.
  • Do not use in areas where the head harness may be exposed directly to flame.
  • The Avon FM50™ filter canisters provided with this equipment do not offer protection from smoke or carbon monoxide.

Misusing the gas mask emergency kit can cause serious harm or death. Avoid these actions:

  • Using the gas mask with filters for firefighting.
  • Modifying, removing or re-configuring any of the system components other than as recommended by the manufacturer.
  • Attaching unapproved equipment or accessories to the respirator mask with filters.
  • Re-using the equipment without appropriate decontamination or following impact or tear damage without inspection and testing, even though contamination or damage may not be apparent.
  • Using the gas mask and filter with non-approved filter canisters.
Resources

PC50™ Brochure

Frequently Asked Questions

Person in mask

The U.S. Government has certain controls over the FM50™ Air Purifying Respirator and prohibits the exporting, selling, transferring, transporting, or shipping of the product outside the U.S.. This restriction applies whether the product is in its original form or has been incorporated into other items without first obtaining approval from the U.S. government, or as authorized by U.S. law and regulations. This product is subject to International Traffic in Arms Regulations (ITAR) XIV (f)(4)..

Product shipped in fulfillment of e-commerce orders may be more than one year old.

PLEASE NOTE ALL SALES ARE FINAL. OPEN BOX RETURNS WILL NOT BE ACCEPTED.
In the rare case of a defective product, please refer to our returns policy and contact customer service for further instructions.