Skip to content
New

FM54™ Air Purifying Respirator Specialist Kit

$1,372.00 USD $1,372.00 USD

The Avon Protection FM54 Air Purifying Respirator provides maximum protection and total flexibility. The FM54 provides improved fire resistance and protection to the face, eyes and respiratory tract from Chemical, Biological, Radiological and Nuclear (CBRN) threats, Riot Agents, Toxic Industrial Chemicals (TICs) and Toxic Industrial Materials (TIMs) while maintaining extreme user flexibility as mission profiles change.

This gas mask kit includes:

  • FM54™ Air Purifying Respirator
  • CBRNCF50 Filter
  • CTCF50 Riot Agent Filter
  • Clear Outsert
  • Sunlight Outsert
  • A Universal Mask Carrier (ideal for creating a gas mask emergency kit)

Product shipped in fulfillment of e-commerce orders may be more than one year old.

PLEASE NOTE ALL SALES ARE FINAL. OPEN BOX RETURNS WILL NOT BE ACCEPTED. 
In the rare case of a defective product, please refer to our returns policy and contact customer service for further instructions.

Size

Performance

Technical Data
CBRN Agent Resistance Requirement FM54 Performance
Mustard Vapor (HD) 36 hours > 36 hours
Mustard Liquid (HD) 36 hours > 36 hours
Sarin (GB) 36 hours > 36 hours
Laboratory protection factor performance (sodium chloride) 2,000 > 10,000
Breathing Performance
Re-breathed CO2 < 1%
Inhalation Resistance 30 L/Min < 5 mm WG
95 L/Min < 12 mm WG
160 L/Min < 23 mm WG
Exhalation Resistance negative pressure mode 85 L/Min < 8 mm WG
160 L/Min < 12 mm WG
Weight
FM54 mask (excluding filter < 0.65 kg (1.43 lbs)
Field of View
Visual Field Score (NIOSH CBRN Standard) 96
Materials Used
FM54 Mask Chlotobutyl / Silicone rubber & Polyurethane
Hydration
Drinking flow rate 230 mL/min

Sizes & Fit

*ALL SALES ARE FINAL. OPEN BOX RETURNS WILL NOT BE ACCEPTED.

Please select the correct size according to the sizing chart guide.

NOTE: For proper mask fit, faces must be clean shaven. Facial hair, sideburns, bangs and headwear may prevent a protective facepiece from forming and/or maintaining a tight-fitting seal on someone’s face. It is recommended the user be clean shaven and/or hair pulled back for sizing and using the respirator to ensure an appropriate seal.

To ensure you have selected the correct size you should perform a negative pressure test. The negative pressure test can be performed by putting the mask on your face, breathe out, then block the inhalation valve and take a deep breath. For the FM50 you will need to block both inhalation valves before taking a breath. The mask should collapse to the face. If you experience a tight seal to your face then the mask has the right fit.

If you are still unsure of your size or are certain you are going to be in a hazardous environment and need to ensure the most accurate sizing you may purchase a Sizing Tool.

*Except in the rare case of defective product. Please contact customer service for further instruction in this instance.

Warnings and Limitations of Use

  • Always perform a negative pressure leak test before using this respirator mask with filters.
  • This gas mask with filters is not suitable for use in confined spaces such as stills, tanks or sewers. This device does not provide supplied breathable air.
  • If you have facial hair or wear glasses, the mask may not seal properly, reducing its protection.
  • Do not use this respirator mask in environments with low oxygen (less than 19.5%) or in areas with airborne contaminants/pollutants the filter can't protect against.
  • Do not use this gas mask and filter in oxygen-enriched atmospheres (> 22.5% Oxygen).
  • Set up, check, donning, doffing, clean, and maintain the gas mask kit in a clean area free of contaminants.
  • Do not use if any system component demonstrates signs of wear or damage.
  • Do not use in areas where the head harness may be exposed directly to flame.
  • The Avon FM50™ filter canisters provided with this equipment do not offer protection from smoke or carbon monoxide.

Misusing the gas mask emergency kit can cause serious harm or death. Avoid these actions:

  • Using the gas mask with filters for firefighting.
  • Modifying, removing or re-configuring any of the system components other than as recommended by the manufacturer.
  • Attaching unapproved equipment or accessories to the respirator mask with filters.
  • Re-using the equipment without appropriate decontamination or following impact or tear damage without inspection and testing, even though contamination or damage may not be apparent.
  • Using the gas mask and filter with non-approved filter canisters.

The U.S. Government has certain controls over the FM54™ Air Purifying Respirator Specialist Kit and prohibits the exporting, selling, transferring, transporting, or shipping of the product outside the U.S. without first obtaining approval from the U.S. government, or as authorized by U.S. law and regulations. This restriction applies whether the product is in its original form or has been incorporated into other items.

Product shipped in fulfillment of e-commerce orders may be more than one year old.

PLEASE NOTE ALL SALES ARE FINAL. OPEN BOX RETURNS WILL NOT BE ACCEPTED. 
In the rare case of a defective product, please refer to our returns policy and contact customer service for further instructions.