Skip to content
New

PC50™ Air Purifying Respirator

$381.00 USD $381.00 USD

MARCH DEAL: Purchase this respirator and get a FREE Sunlight Outsert AND Clear Outsert. Add items to cart and use code VISORDEAL at checkout. 

The Avon Protection PC50™ protective mask is based on the widely deployed 50 Series masks, and is designed to provide protection in dangerous and contaminated environments that demand a robust, field-proven competitively-priced military pedigree product that meets their operational needs.

Approved as a NON-CBRN respiratory device, it provides protection in dangerous and contaminated environments, against certain solid and liquid respirable particles, gases, vapors and splashes of liquid chemicals.

The PC50 was specifically developed for those who have price-sensitive budgets. It has been used by First Responders,  Correctional Officers, Riot Control, Border Patrol, Plant Security and other NON-CBRN requirements.

The PC50 is available in three sizes, with either left or right hand 40mm canister mounts that accept traditional or conformal filters. The standard communication port allows the ability to integrate with existing radios. The PC50 may be fitted with a vision correction system and a variety of outserts for specific operational situations. 

The U.S. Government has certain controls over the PC50™ Air Purifying Respirator and prohibits the exporting, selling, transferring, transporting, or shipping of the product outside the U.S. This restriction applies whether the product is in its original form or has been incorporated into other items without first obtaining approval from the U.S. government, or as authorized by U.S. law and regulations. This product is subject to Export Administration Regulations (EAR) with a classification of 1A004.

Product shipped in fulfillment of e-commerce orders may be more than one year old.



Size: small
Performance
The PC50 is approved for use with the CTCF50 Canister providing protection against CS/CN agents in both vapor and aerosol form and particulate matter. The PC50 is also approved for use with the CFP100 Canister providing protection against particulates only. And NIOSH approved (TC-14G-0316) (TC-84A-9233).

Breathing Performance PC50 Performance
Inhalation resistance without filter:
30 l/min 0.5 mbar
90 l/min 1.5mbar
160 l/min 3.5 mbar
Exhalation resistance 85l/min (with CTCF50 filter) 1.9 mbar
Mask weight (excluding filter) 550 grams
Visual Field Score (VFS) >90
Sizing
*ALL SALES ARE FINAL. OPEN BOX RETURNS WILL NOT BE ACCEPTED.

Please select the correct size according to the sizing chart guide found in the photo gallery for this product.

NOTE: For proper mask fit, faces must be clean shaven.

Facial hair, sideburns, bangs and headwear may prevent a protective facepiece from forming and/or maintaining a tight-fitting seal on someone’s face. It is recommended the user be clean shaven and/or hair pulled back for sizing and using the respirator to ensure an appropriate seal.

To ensure you have selected the correct size you should perform a negative pressure test. The negative pressure test can be performed by putting the mask on your face, breathe out, then block the inhalation valve and take a deep breath. For the PC50 you will need to block both inhalation valves before taking a breath. The mask should collapse to the face. If you experience a tight seal to your face then the mask has the right fit.

If you are still unsure of your size or are certain you are going to be in a hazardous environment and need to ensure the most accurate sizing you may purchase a Sizing Tool.

*Except in the rare case of defective product. Please contact customer service for further instruction in this instance.

Warnings and Limitations of Use
  • Always perform a satisfactory negative pressure leak test before using this respirator.
  • Do not use in confined spaces such as stills, tanks or sewers. This device does not provide supplied breathable air.
  • It is unlikely that the requirements for inward leakage of the system will be met if facial hair, or spectacle side arms pass under the face seal of the full face mask.
  • Do not use this equipment in Oxygen deficient atmospheres (<19.5% Oxygen) or for airborne contaminants or pollutants for which the approved filter canister(s) will not provide adequate protection.
  • Do not use this equipment in Oxygen enriched atmospheres (> 22.5% Oxygen).
  • System set-up, pre-check, donning, doffing, cleaning and maintenance must be performed in an area known to be free of contaminants.
  • Do not use if any system component demonstrates signs of wear or damage.
  • Do not use in areas where the head harness may be exposed directly to flame.

Potential misuse of the equipment may result in serious, irreversible respiratory harm or death. These actions include:

  • Firefighting.
  • Modifying, removing or re-configuring any of the system components other than as recommended by the manufacturer.
  • Adapting the system to accommodate attachments or apparatus not approved for use by the manufacturer.
  • Re-using the equipment without appropriate decontamination or following impact or tear damage without inspection and testing, even though contamination or damage may not be apparent.
  • Use with unapproved filter canisters.
Resources

PC50™ Brochure

Frequently Asked Questions